The six MOSFETs in a three-phase inverter do most of the hard work in a brushless DC motor drive, and they produce most of the heat. Choose them well and the drive runs cool, efficient and quiet on the spectrum analyzer. Choose them badly and you get hot boards, failed stress tests and a second layout. The good news is that selection follows a repeatable process. You do not need to be a power-electronics specialist to get it right, but you do need to work through the steps in order.
This guide walks through that process for drives that run from 24 V to 36 V supplies, where a 60 V MOSFET is the usual choice. It uses one widely used part, the Texas Instruments CSD18540Q5B, as a worked example, with numbers you can adapt to your own design.
How the MOSFETs are used in a BLDC drive
A three-phase inverter has three half bridges, one per motor phase. Each half bridge has a high-side MOSFET connected to the supply and a low-side MOSFET connected to ground. The controller switches these devices with pulse-width modulation to shape the current in the motor windings.
At any instant, current flows from the supply through one high-side device, through two motor windings, and back through one low-side device. Each MOSFET therefore sees the full phase current while it conducts. Between the turn-off of one device and the turn-on of its partner there is a short dead time, during which current flows through a body diode.
Losses come from three sources: conduction loss while a device is on, switching loss during each transition, and diode loss during dead time. Selection is about keeping the total low enough that the junction temperature stays within limits under the worst conditions your product will see.
Step 1: Set the voltage rating
The drain-to-source rating must exceed the highest voltage the device will ever see, with margin. That voltage is not the nominal supply. It is the maximum supply plus the ringing that occurs when current is interrupted through stray inductance, plus any rise in the supply when the motor regenerates during braking.
A common rule is to keep the worst-case voltage below 80 percent of the rating. For a 60 V device that means 48 V.
- A 24 V system, such as a 6-cell lithium pack at 25.2 V full charge, leaves a great deal of margin with a 60 V device. A 40 V device is also possible if the layout is tight.
- A 36 V system, such as a 10-cell pack at 42 V full charge, fits a 60 V device with reasonable margin for spikes.
- A 48 V system, such as a 13-cell pack at 54.6 V full charge, is too close. Use 80 V or 100 V devices.
Our example device is rated at 60 V, so it suits 24 V and 36 V drives.
Step 2: Define the current
You need two numbers: the continuous RMS phase current at rated load, and the peak current during starting, stall or acceleration. The continuous figure drives the thermal design. The peak figure must stay inside the safe operating area and below the current limit of your controller.
For the worked example, assume a 36 V drive delivering 20 A RMS per phase continuously, with 50 A peaks for a few seconds during acceleration, and a PWM frequency of 20 kHz.
Step 3: Calculate conduction loss
Conduction loss in a MOSFET is the square of the RMS current multiplied by the on-resistance. The on-resistance to use is the hot value, not the room-temperature value on the front page of the datasheet.
The CSD18540Q5B has a typical on-resistance of 1.8 milliohms at 10 V gate drive, with a maximum of 2.2 milliohms. On-resistance rises with temperature. A factor of about 1.6 at a junction temperature of 125 degrees Celsius is typical for this class of device, and the datasheet provides a curve for the exact figure. Taking the maximum value and the temperature factor gives about 3.5 milliohms.
In most modulation schemes each MOSFET conducts for only part of the electrical cycle. As a rough guide, the RMS current in one device is around 0.7 times the RMS phase current. For 20 A in the phase, that is 14 A in each MOSFET.
Conduction loss per device is then 14 A squared times 3.5 milliohms, which is about 0.7 W. During 50 A peaks the device current is about 35 A and the loss rises to about 4.3 W for as long as the peak lasts.
Step 4: Calculate switching loss
Each time a MOSFET turns on or off under load, it spends a short time with both voltage across it and current through it. The energy lost in each transition depends on how quickly the gate driver moves the device through that region, which is set by the gate-to-drain charge and the driver current.
A simple estimate of switching loss is one half of the bus voltage, times the current, times the sum of the rise and fall times, times the switching frequency. The CSD18540Q5B has a gate-to-drain charge of 6.7 nC and a total gate charge of 41 nC at 10 V. With a driver delivering around 1 A, the voltage transition takes on the order of 10 to 20 nanoseconds. Motor drives often slow this deliberately with gate resistors, so take 50 nanoseconds each for turn-on and turn-off as a conservative figure.
At 36 V, 20 A, 100 nanoseconds total and 20 kHz, the estimate is 0.5 times 36 times 20 times 100 nanoseconds times 20,000, which is about 0.7 W. In practice only the device that performs hard switching in each half bridge carries this loss, and its partner switches at nearly zero voltage.
The lesson from the numbers is that at 20 kHz, conduction and switching losses are of similar size for this device. At higher frequencies switching loss dominates, and gate charge becomes the more important parameter.
Step 5: Add gate drive and dead-time losses
Gate drive power is the total gate charge times the gate voltage times the frequency. For 41 nC at 10 V and 20 kHz, that is about 8 mW per device, dissipated in the driver and gate resistors rather than the MOSFET. It is small here, but it scales with frequency and with the number of devices in parallel.
During dead time the body diode carries the phase current. The loss is the diode forward voltage times the current times the dead time, twice per cycle. With 0.8 V, 20 A, 200 nanoseconds of dead time and 20 kHz, that is about 0.13 W. Keeping dead time short helps, as long as there is no overlap.
Step 6: Check the thermal design
Add the losses for the worst-placed device. In our example that is roughly 0.7 W of conduction loss, 0.7 W of switching loss and 0.13 W of diode loss, about 1.5 W in total.
Now work out the temperature rise. The datasheet gives a junction-to-case thermal resistance below 1 degree Celsius per watt for this package and a junction-to-ambient figure of around 40 degrees Celsius per watt on a standard test board with one square inch of copper. A real motor-drive board with thermal vias, thick copper and a heatsink or chassis mount will be considerably better than the test-board figure.
At 40 degrees Celsius per watt, 1.5 W gives a 60 degree rise, which is acceptable in a 50 degree ambient but leaves little margin. Improve the copper area or add a heatsink and the rise falls quickly. Remember that six devices share the board and heat each other, so measure on a prototype rather than trusting the single-device figure.
Also check the peak condition. At 50 A phase current the total loss per device rises to several watts. Whether that is safe depends on how long the peak lasts and on the thermal mass of the board. The transient thermal impedance curve in the datasheet shows how the device responds to short pulses.
Step 7: Match the gate driver
The MOSFET and gate driver have to suit each other.
- Gate voltage. The example device is fully specified at 10 V and also characterized at 4.5 V, where on-resistance is 2.6 milliohms typical. A 10 V or 12 V driver gives the lowest loss. The gate is rated to 20 V, so do not exceed that, including ringing.
- Threshold. The typical threshold is 1.9 V. That is low enough for easy drive and high enough to resist modest noise, but layout still matters.
- Miller turn-on. When the opposite device in a half bridge switches, the fast voltage change couples through the gate-to-drain capacitance and tries to lift the gate. A low ratio of gate-to-drain charge to gate-to-source charge helps. The example device has 6.7 nC against 8.8 nC, a favorable ratio. A strong pull-down in the driver and a short gate loop help further.
- Bootstrap supply. The high-side driver is usually powered from a bootstrap capacitor. Size it to supply the gate charge with only a small voltage drop, and confirm it can recharge at your maximum duty cycle.
Step 8: Consider package and layout
The 5 mm by 6 mm power package is the standard for drives in this power range. It has a large exposed drain pad that carries both current and heat, and it is offered by every major MOSFET maker, which makes second sourcing practical.
Layout has as much effect on performance as the choice of part.
- Keep the loop formed by the bus capacitor, high-side device and low-side device as small as possible. This loop’s inductance sets the voltage spike at turn-off.
- Place ceramic capacitors directly across each half bridge.
- Route each gate trace close to its return path, and give every device its own gate resistor.
- Use arrays of thermal vias under the drain pads and connect them to wide copper areas.
- Keep current-sense traces away from the switch nodes and route them as differential pairs.
Sourcing the example part
If the calculations point you to this device, you will need a supplier. Verified Electronics is a CSD18540Q5B distributor that lists the part alongside other Texas Instruments components and sends parts for third-party testing, which is useful when you are buying power devices for a production run.
Step 9: Verify on the bench
Calculation gets you to a sensible first choice. Measurement confirms it.
- Probe the switch node with a short ground lead and check the peak voltage at maximum current. Keep it under 80 percent of the rating.
- Probe the low-side gate during the high-side turn-on and look for a bump approaching the threshold.
- Run the drive at rated load until temperatures settle, then measure the package temperature of each device.
- Run stall and rapid-reversal tests and confirm the current limit acts before the devices leave their safe operating area.
- Check braking. Regenerated energy raises the bus voltage unless something absorbs it.
Common mistakes
- Using room-temperature on-resistance in loss calculations.
- Choosing the lowest on-resistance available without looking at gate charge, then finding the driver overheats.
- Selecting a voltage rating from the nominal supply and ignoring spikes and regeneration.
- Sharing one gate resistor between paralleled devices.
- Assuming the datasheet current rating is usable. It is set by ideal cooling, and real designs are limited by temperature long before that figure.
Frequently asked questions
Why not use a 100 V MOSFET for extra margin? For the same package, a higher voltage rating means higher on-resistance and usually higher gate charge. Use the lowest rating that gives adequate margin.
Should I parallel devices or pick a bigger one? Paralleling spreads heat over more board area and reduces conduction loss, but doubles gate charge. It is a good option above about 30 A continuous in this package.
What PWM frequency should I use? 16 to 20 kHz keeps the drive out of the audible range with modest switching loss. Higher frequencies reduce current ripple in low-inductance motors but raise losses.
How much dead time do I need? Enough that both devices are never on together across temperature and part tolerance. Start from the gate driver’s recommendation and verify with a scope.
Summary
Choosing a 60 V MOSFET for a BLDC drive comes down to a sequence: set the voltage rating from the worst-case bus voltage, define the RMS and peak currents, calculate conduction and switching losses with hot on-resistance, check the temperature rise, match the gate driver, and confirm everything on the bench. For 24 V and 36 V drives, a device such as the CSD18540Q5B, with 1.8 milliohms typical on-resistance and 41 nC of gate charge, gives low losses at typical PWM frequencies. Always take final figures from the current manufacturer datasheet for the part you select.